Back to Elegoo
¶
Issue Description
The hotend does not heat as expected.
¶
Reasons
The cable of the ceramic heating plate of the hotend is loose.
The ceramic heating plate is damaged.
¶
Troubleshooting Steps
¶
Tools needed for troubleshooting
A 2.5 mm Allen key
Turn the power switch OFF (symbol "〇") and unplug the power supply cable.
Remove the lid.
Open the front cover of the tool head.
Loosen the screws securing the hotend with a 2.5 mm Allen key and remove the hotend.
Re-plug the cable of the hotend ceramic heating plate.
If the error code disappears, it indicates that the issue has been resolved.
If the error code still occurs after re-plugging, it indicates that the ceramic heating plate is damaged and needs to be replaced.