Turn the power switch OFF (symbol O).
Unplug the power supply cable.
Remove the front cover of the tool head.
Unplug the model cooling fan cable.


Loosen the screws securing the hotend kit with a 2.5 mm Allen key.
Remove the screws with a pair of tweezers.

Unplug the ceramic heating plate cable and the thermistor cable.
Remove the old hotend kit.


Prepare the new hotend kit.
Plug in the ceramic heating plate cable and the thermistor cable.


Prepare the front cover of the tool head.
Plug in the model cooling fan cable.


Plug in the power supply cable.
Turn the power switch ON (symbol |).
On the touch screen, select Settings > Calibration > One-Click Self-Check.
The printer is ready for use after the calibration is complete.